LED retrofit with ECG/CCG – safe conversion to LED tubes

When retrofitting fluorescent tubes to LED tubes, the existing ECG or CCG in the luminaire is removed and the LED tube is operated directly on 230 V, without a starter and without control gear. This significantly increases safety, efficiency, and service life. Here you can learn why an integrated driver is essential and how retrofit LED tubes operate correctly in accordance with standards.

Published December 1st, 2025

 

By eliminating ECGs and CCGs, the entire luminaire becomes significantly lower-maintenance and independent of proprietary manufacturer systems. An LED tube with an integrated driver can be operated directly on 230 V and, if required, replaced without a qualified electrician. High-quality solutions such as the GLT LED TUBE provide flicker-free light, long service life, and high energy savings – offering a technically safe and sustainable modernisation solution for all existing luminaires.

LED Retrofit with GLT LED TUBE - advantages at a glance

Langlebig & energieeffizient

130.000 h
service life

Langlebig & energieeffizient

IEC EN 62776
safety

Langlebig & energieeffizient

-40°C bis +70°C
industrial-grade

Langlebig & energieeffizient

up to 80%
energy saving

Advantages of the LED tube without ballast

Not every LED tube is suitable for LED retrofit applications. Decisive quality criteria include service life, energy efficiency, thermal management, materials, switching durability and an integrated driver. These factors directly influence operational reliability, maintenance expenditure and total cost of ownership.

In addition, compliance with the EU Ecodesign Directive is mandatory to ensure reliable operation within a temperature range of -20°C to +60°C.

Technical advantages – GLT LED TUBE

  • Temperature resistance from -40°C to +70°C.
  • Energy efficiency class A, up to 210 lm/W.
  • Driver electronics based entirely on 100% SMD technology.
  • Suitable for 230 V AC/DC operation.
  • Aluminium profile serving as both structural carrier and active heat sink.
  • Repairable and recyclable (up to 90%).

Economic advantages – GLT LED TUBE

  • Energy savings of up to 80%.
  • Minimal maintenance costs due to long service life and simple lamp replacement (1:1 replacement).
  • Service life L70 = 130,000 operating hours (including power supply).
  • Failure rate of just 1% within 50,000 operating hours.
  • No dependency on specific ballast or luminaire manufacturers.
  • Rental model instead of capital purchase – no upfront investment required.

Standards & CE compliance

  • LED retrofit in accordance with IEC EN 62776.
  • Continued CE conformity of the overall installation.
  • Compliance with RoHS, EU Ecodesign and ESG requirements.

 

Technical Highlights GLT LED TUBE

 

GLT LED TUBE

Competitors

Energy consumption (Watt) 16,8 W 24 - 45 W
CO₂ savings appr. 75% appr. 35 - 50%
Temperaturerange ‑40° bis +70 °C ‑30° bis +45 °C
Lifetime 130.000 h 30.000 - 50.000 h
Manufacturing / Quality Germany China / Korea
Break resistant IK 10 No
Remt / Leasing Ja No
Recycling share up to 90 % No

IEC/EN 62776 standard explained – safety with ECG/CCG

The EN 62776 standard defines how LED tubes can be safely operated without a starter and without electronic control gear (ECG). It specifies how G5/G13 luminaires must be correctly rewired to comply with CE conformity and fire safety requirements.

LED flackert - Ursachen & Lösung

Das Flackern einer LED-Röhre kommt vor allem gelegentlich in Büro- und Verwaltungsgebäuden vor. Die Ursache liegt praktisch nie an der LED selbst, sondern an der elektrischen Ansteuerung, also dem Zusammenspiel zwischen LED-Treiber, Vorschaltgerät und Netzspannung. 

LED tubes without control gear – why this solution is safer

Starters and control gear in LED tube installations are among the most common sources of faults in luminaires with G5/G13 sockets. By using an LED tube with an integrated driver, these components are completely eliminated.

The system becomes safer, more efficient, and more durable – without compatibility issues, without flickering, and without dependence on proprietary luminaire manufacturers. At the same time, the luminaire remains standards-compliant and future-proof.

Häufige Fragen zu LED-Röhren T5 und T8

Warum sollte man bei LED-Retrofit das EVG oder KVG entfernen?

EVG und KVG stammen aus der Leuchtstofftechnik und sind für LED-Systeme überflüssig. Sie verursachen häufig Flackern, Spannungsspitzen, Startprobleme und unnötige Energieverluste.

Die Norm IEC EN 62776 sieht deshalb vor, diese Vorschaltgeräte beim Retrofit zu überbrücken. Erst dann kann eine LED-Röhre ohne Starter direkt an 230 V sicher und effizient betrieben werden.

Wie erfolgt der Wechsel bei einem Konventionellen Vorschaltgerät (KVG)?

Bei Armaturen mit einem konventionellen Vorschaltgerät ersetzen Sie den Starter durch einen Dummy. Danach montieren Sie die GLT LED TUBE anstelle der alten Leuchtstoffröhre.

Starterwechsel bei KVG

Wie erfolgt der Wechsel bei einem Elektronischen Vorschaltgerät (EVG)?

Die Montage einer GLT LED TUBE in eine EVG-Armatur muss durch einen Fachmann erfolgen. Dank der direkten Stromversorgung der GLT LED TUBE fällt der Störfaktor Vorschaltgerät weg und die Betriebszuverlässigkeit wird erhöht.

EVG-Installation

Kann ich eine LED-Röhre selbst wechseln?

Ja. Nach der Umverdrahtung (EVG) durch eine Elektrofachkraft kann die LED-Röhre anschließend ohne Fachkenntnisse gewechselt werden oder durch den Ersatz des Starters durch einen Dummy (KVG). Das LED Leuchtmittel wird einfach eingesetzt und direkt über 230 V versorgt – kein Starter, kein EVG, keine zusätzlichen Bauteile. Das reduziert langfristig Wartungsaufwand und Kosten erheblich.

Warum flackern LED-Röhren?

Flackern entsteht fast nie durch die LED selbst, sondern durch alte oder inkompatible Vorschaltgeräte. EVG und KVG geben Taktungen, Restspannungen oder Schaltimpulse an die LED weiter. Die zuverlässige Lösung ist die Stilllegung des Vorschaltgeräts und der Betrieb der LED-Röhre mit integriertem Treiber direkt an 230 V – so arbeiten Retrofit-Leuchten flimmerfrei und stabil.

Clear recommendations tailored to each application

Have the retrofit assessed for compliance with applicable standards.

We plan your LED retrofit – standards-compliant and cost-effective.


Close